Industrial dehumidifier in a working installation

DVC-40 Industrial dehumidifier

DVC-40 Industrial dehumidifier front view

Industrial dehumidifier

  • Sheet metal body with an external anti-corrosion coating
  • Panasonic / Haili compressors for stable condensing performance
  • Hydrophilic aluminium fins for faster condensate formation
  • Turbo fan and full-copper sealed motor for continuous running
Capacity:40 kg/hPower:380 V / 50 HzCategory:Industrial dehumidifiers

Technical specifications

ModelDVC-40
Power supply380 V / 50 Hz
RefrigerantR22
CompressorHaili
Rated inputOn request
AirflowOn request
Air pathFront return, top supply
Working temperature5 – 38 °C

Values are published catalogue data. Where a site condition differs, the approved drawing for the order takes precedence.

DVC-40 Industrial dehumidifier front view

Cabinet photographs of the current series. Grille layout and control arrangement follow the approved drawing for each order.

Heavy-duty condensing units rated in kilograms per hour for workshops, warehouses and equipment rooms.

Industrial dehumidifier 40 kg/h belongs to the industrial dehumidifiers platform. Enquiries are answered within one business day.

Using the DVC-40

What the rating means

DVC-40 is rated at 40 kg/h, which is about 960 kg, or roughly 960 litres, of water a day. Working figures of that kind are useful in two directions: they convert a moisture load into a model, and they show how much water the drain has to carry away on a wet day.

Catalogue capacity is quoted at a defined test condition, and the accepted figure for an order is the one on the approved drawing. Warmer, wetter entering air gives the coil more water to remove per cubic metre; cooler or drier air gives less. Any model quoted for a project is checked against that condition rather than the headline number.

Installation and air path

Industrial cabinets are built to be ducted as well as free-blown. Return air enters the front grille and leaves the top supply, so where a ceiling void or an adjacent plant room exists, the supply can be carried through ductwork instead of blowing into the space the unit is drying.

On this frame, the published working range is 5 – 38 °C, air path front return, top supply.

What to send with an enquiry

  • Room volume or air-change rate, with the height the air actually occupies.
  • Entering air temperature and relative humidity in the worst week of the year.
  • The band that has to be held, and the tolerance the process really needs.
  • Fresh-air volume and its condition, where the room is ventilated.
  • Internal moisture: people, wash-down, open tanks, wet product coming in.
  • Drain route and the power available at the mounting position.

With those answers the model is checked against the moisture load. If the frame is wrong for the room, the reply names the platform that fits instead of pushing this one.

Where this model stops

Below the published working temperature a condensing coil loses capacity and begins to frost, and the defrost cycle takes back part of the running time. Rooms held under roughly 10 °C, or at a dew point a coil cannot reach, belong to the desiccant rotor platform.

Desiccant rotor range

Drawings, electrical data and the installation manual are released with the order, so the site works from the document that matches the frame delivered.

Questions about the DVC-40

How much room can the DVC-40 dry?

DVC-40 is rated at 40 kg/h, moving On request. Room size on its own does not settle the model: the load is the air-change rate multiplied by the moisture difference between outdoor air and the band you need, plus whatever the process adds. Send the volume, the air-change rate and the target band and the same calculation comes back with the model and the figure behind it.

How is the DVC-40 installed?

Yes. On the DVC-40, return air enters the front grille and leaves through the top supply, so ductwork can carry treated air to another part of the hall. Where the unit runs free-blowing, it is placed so the supply mixes with room air before the sensor reads it again.

What power supply does the DVC-40 need?

The published supply is 380 V / 50 Hz. Cable size and protection follow the installed configuration, so the circuit at the mounting position is checked against the approved drawing rather than against the catalogue page.

How cold can the DVC-40 work?

The published working range is 5 – 38 °C. Below that range a condensing coil frosts, defrost cycles take back running time and useful output falls away, so colder rooms are quoted on a desiccant rotor platform instead.

Is the 40 kg/h figure guaranteed on site?

The figure is quoted at a defined test condition. Warmer, wetter entering air gives the coil more water to remove per cubic metre; cooler or drier air gives less. For an order the condition and the required removal rate are written on the approved drawing, which takes precedence over the catalogue figure. Enquiries are answered within one business day.