Constant temperature and humidity unit in a working installation

DVH-10 Constant temperature and humidity unit

DVH-10 Constant temperature and humidity unit front view

Constant temperature and humidity unit

  • Cooling, heating, humidification and dehumidification in one cabinet
  • Stable temperature and humidity band for test rooms and laboratories
  • Configured per project with the required control tolerance
Capacity:Configured per projectPower:On requestCategory:Constant temperature and humidity units

Technical specifications

ModelDVH-10
FunctionCooling, heating, humidification and dehumidification
ControlTemperature and humidity held within the agreed band
InstallationFloor-standing indoor unit with remote condensing unit
ToleranceSet per project
DocumentationSpecification sheet on request

Values are published catalogue data. Where a site condition differs, the approved drawing for the order takes precedence.

DVH-10 Constant temperature and humidity unit front view

Cabinet photographs of the current series. Grille layout and control arrangement follow the approved drawing for each order.

Combined cooling, heating, humidification and dehumidification for rooms that must hold both temperature and humidity.

Constant temperature and humidity unit configured per project belongs to the constant temperature and humidity units platform. Model range and capacity are confirmed per project. Ask for the current specification sheet.

Using the DVH-10

What the rating means

DVH-10 is rated at configured per project. Working figures of that kind are useful in two directions: they convert a moisture load into a model, and they show how much water the drain has to carry away on a wet day.

Catalogue capacity is quoted at a defined test condition, and the accepted figure for an order is the one on the approved drawing. Warmer, wetter entering air gives the coil more water to remove per cubic metre; cooler or drier air gives less. Any model quoted for a project is checked against that condition rather than the headline number.

Installation and air path

One cabinet carries cooling, heating, humidification and dehumidification, so the site has to provide power for the configured load, a condensate drain and, where humidification is included, a water supply. The control tolerance is what the unit is built around.

On this frame, the electrical and airflow data are confirmed with the order drawing.

What to send with an enquiry

  • Room volume or air-change rate, with the height the air actually occupies.
  • Entering air temperature and relative humidity in the worst week of the year.
  • The band that has to be held, and the tolerance the process really needs.
  • Fresh-air volume and its condition, where the room is ventilated.
  • Internal moisture: people, wash-down, open tanks, wet product coming in.
  • Drain route and the power available at the mounting position.

With those answers the model is checked against the moisture load. If the frame is wrong for the room, the reply names the platform that fits instead of pushing this one.

Where this model stops

The published configuration is a starting point for the project, not a catalogue rating. Loads are calculated from the room, the product inside it and the band that has to be held, then the cabinet is configured to match.

All platforms

Drawings, electrical data and the installation manual are released with the order, so the site works from the document that matches the frame delivered.

Questions about the DVH-10

What can the DVH-10 be configured to hold?

The DVH-10 is configured per project rather than rated off a single catalogue point. The band, the tolerance and the load inside the room decide the cooling, heating, humidification and dehumidification capacity built into the cabinet. Send the set point, the tolerance, the equipment load and the air-change rate and the configuration is stated against them.

How is the DVH-10 installed?

Cooling, heating, humidification and dehumidification in one cabinet, configured to the band and tolerance of the project. The published DVH-10 configuration is a starting point; the order drawing states what is built.

What power supply does the DVH-10 need?

The supply is confirmed on the order drawing. Cable size and protection follow the installed configuration, so the circuit at the mounting position is checked against the approved drawing rather than against the catalogue page.

How cold can the DVH-10 work?

The band is agreed per project, so the temperature and the tolerance are stated before the cabinet is configured.

How is the band for the DVH-10 confirmed?

The band is confirmed on the approved drawing for the order, together with the tolerance, the control method and the sensor position. Catalogue configurations are starting points; the drawing states what the cabinet is built and commissioned to hold. Enquiries are answered within one business day.