Floor-standing dehumidifier in a working installation

DVS-90 Floor-standing dehumidifier

DVS-90 Floor-standing dehumidifier front view

Floor-standing dehumidifier

  • Sheet metal body with an external anti-corrosion coating
  • Panasonic / Haili compressors for stable condensing performance
  • Hydrophilic aluminium fins for faster condensate formation
  • Turbo fan and full-copper sealed motor for continuous running
Capacity:90 L/dayPower:220 V / 50 HzCategory:Commercial dehumidifiers

Technical specifications

ModelDVS-90
Power supply220 V / 50 Hz
Rated input1000 W
Airflow950 m³/h
Noise< 45 dB(A)
Working temperature15 – 38 °C
Dimensions475 × 430 × 850 mm
Weight50 kg

Values are published catalogue data. Where a site condition differs, the approved drawing for the order takes precedence.

DVS-90 Floor-standing dehumidifier front view

Cabinet photographs of the current series. Grille layout and control arrangement follow the approved drawing for each order.

Plug-in condensing units with continuous or bucket drainage for halls, basements and storage areas.

Floor-standing dehumidifier 90 l/day belongs to the commercial dehumidifiers platform. Enquiries are answered within one business day.

Using the DVS-90

What the rating means

DVS-90 is rated at 90 l/day, which is about 3.8 kg/h. Working figures of that kind are useful in two directions: they convert a moisture load into a model, and they show how much water the drain has to carry away on a wet day.

Catalogue capacity is quoted at a defined test condition, and the accepted figure for an order is the one on the approved drawing. Warmer, wetter entering air gives the coil more water to remove per cubic metre; cooler or drier air gives less. Any model quoted for a project is checked against that condition rather than the headline number.

Installation and air path

These units move on castors and run on continuous drainage, so the same cabinet can work in a basement this month and a storage room next. Rated capacity describes the frame, not the socket: the printed input has to be checked against the circuit that will feed it.

On this frame, the published working range is 15 – 38 °C, the fan moves 950 m³/h, the cabinet measures 475 × 430 × 850 mm, rated noise is < 45 dB(A).

What to send with an enquiry

  • Room volume or air-change rate, with the height the air actually occupies.
  • Entering air temperature and relative humidity in the worst week of the year.
  • The band that has to be held, and the tolerance the process really needs.
  • Fresh-air volume and its condition, where the room is ventilated.
  • Internal moisture: people, wash-down, open tanks, wet product coming in.
  • Drain route and the power available at the mounting position.

With those answers the model is checked against the moisture load. If the frame is wrong for the room, the reply names the platform that fits instead of pushing this one.

Where this model stops

A plug-in condensing unit is the practical answer while the room stays in its published working range. Once the air is cold enough for the coil to ice, or the target dew point drops below what a coil can hold, the duty moves to a rotor unit.

Desiccant rotor range

Drawings, electrical data and the installation manual are released with the order, so the site works from the document that matches the frame delivered.

Questions about the DVS-90

How much room can the DVS-90 dry?

DVS-90 is rated at 90 l/day, moving 950 m³/h. Room size on its own does not settle the model: the load is the air-change rate multiplied by the moisture difference between outdoor air and the band you need, plus whatever the process adds. Send the volume, the air-change rate and the target band and the same calculation comes back with the model and the figure behind it.

How is the DVS-90 installed?

No building work is needed. The DVS-90 runs on castors with continuous drainage, so the site provides a power point and a drain or collection point. The published input is checked against the circuit that will feed it before the cabinet is moved into place.

What power supply does the DVS-90 need?

The published supply is 220 V / 50 Hz. Cable size and protection follow the installed configuration, so the circuit at the mounting position is checked against the approved drawing rather than against the catalogue page.

How cold can the DVS-90 work?

The published working range is 15 – 38 °C. Below that range a condensing coil frosts, defrost cycles take back running time and useful output falls away, so colder rooms are quoted on a desiccant rotor platform instead.

Is the 90 l/day figure guaranteed on site?

The figure is quoted at a defined test condition. Warmer, wetter entering air gives the coil more water to remove per cubic metre; cooler or drier air gives less. For an order the condition and the required removal rate are written on the approved drawing, which takes precedence over the catalogue figure. Enquiries are answered within one business day.